JR4000 Series

Desktop Robot JR4000 Series

New flagship model expands your possibilities even further…

Product Lineup

How to Read the Model Code

ExampleExample

*Scroll Horizontally

(1)
Device Type
(2)
X-Y Axes
Stroke(mm)
(3)
Number of Axes
(4)
Encoder*1
(5)
Operation Panel Specifications
(6)
Power Supply Specifications
(7)
CE Declaration
JR4000 Series
20:200×200
30:300×320
40:400×400
50:510×510
60:510×620
3:
3 Axes
4:
4 Axes
E:Encoder Included
N:Without Encoder
A:Installed Switch Spec
B:Switchbox Spec
C:Custom Switch Spec
0:100-120/200-240V 50/60Hz (No outlet)
1:100-120V 50/60Hz (100V outlet)*2
2:200-240V 50/60Hz (200V outlet)*2
A:Not Declared
(for sale in Japan only)
B:Declared
(Power Supply
Specifications:0 only)
  • *1 Motor Synchronization Error Detection Function
  • *2 The JR4200 CE Declared, with I/O-S2 added type has no outlet.

Product Lineup

*Scroll Horizontally

JR4203 JR4303 JR4403・4404 JR4503 JR4603
Model JR4203 JR4204 JR4303 JR4304 JR4403 JR4404 JR4503 JR4504 JR4603 JR4604
X-Y Axes Stroke(mm) 200×200 300×320 400×400 510×510 510×620
Number of Axes 3 4 3 4 3 4 3 4 3 4
Encoder E:Encoder Included / N:Without Encoder
Operation Panel Specifications ※This example is for the JR4200 Series.
     
A: Installed Switch Spec  B: Switchbox Spec  C: Custom Switch Spec
Power Supply Specifications 0: 100-120/200-240V 50/60Hz (No outlet)
1: 100-120V 50/60Hz (100V outlet)*1
2: 200-240V 50/60Hz (200V outlet)*1
Optional Specifications Field Network
(CC-Link, EtherNet/IP, PROFINET)
I/O-SYS Add-on
(16 inputs / 16 outputs)
I/O-1 Add-on
(16 inputs / 14 outputs)
I/O-MT Add-on
(for controls
auxiliary axes)
ENC-IN Add-on *2
(for external
encoder value input)
I/O-S *3
(for interlock
device connection)
I/O-S2 *3
(for interlock
device connection)
- -
Rear Side LAN Port
Double Sided - - Standard Standard - - - -
Elevated Column
(Open Height Variation)
Optional Switch*4
Added built-in
I/O power supply
(DC24V rated 2.1A)
COM1・2・3*2 Add-on
(for external devices)
Ejector (air suction
for screw tightening)
  • *1 The JR4200 CE Declared, with I/O-S2 added type has no outlet.
  • *2 Either only the ENC-IN connector or only the COM3 connector is available, but not both.
  • *3 Either only I/O-S or only I/O-S2 is available, but not both.
  • *4 With the Type B and Type C Operation Panels, the Optional Switch is added to the Switchbox.
Please Ask About Special Specifications

Do you need a customized design?
We offer several variations to meet specific size and configuration requirements.

Contact Us

Test and Try

Test your process on our machines. Please contact us for more information.

Customer Support